PINPOINT TEST A : THE REVERSING LAMP IS INOPERATIVE |
TEST CONDITIONS | DETAILS/RESULTS/ACTIONS |
A1: CHECK FUSE F13 (15 A) (CJB). |
| 1 Ignition switch in position 0. |
| 2 Disconnect Fuse F13 (15 A) (CJB). |
| 3 CHECK Fuse F13 (15 A) (CJB). |
| Is the fuse OK.? Yes No RENEW fuse F13 (15 A) and check the operation of the system. If the fuse blows again, LOCATE and RECTIFY the short to ground using the Wiring Diagrams. CHECK the operation of the system. |
A2: CHECK THE VOLTAGE SUPPLY TO FUSE F13 (15A) (CJB) FOR OPEN CIRCUIT |
| 1 Connect Fuse F13 (15 A) (CJB). |
| 2 Ignition switch in position II. |
| 3 Measure the voltage between fuse F13 (15 A) (CJB) and ground. |
| Is battery voltage measured? Yes No LOCATE and RECTIFY the break in the voltage supply to fuse F13 (CJB) using the Wiring Diagrams. If necessary RENEW the CJB. CHECK the operation of the system. |
A3: CHECK THE VOLTAGE AT THE REVERSING LAMP SWITCH |
| 1 Ignition switch in position 0. |
| 2 Disconnect Reversing lamp switch from connector C72. |
| 3 Ignition switch in position II. |
| 4 Measure the voltage between the reversing lamp switch, connector C72, pin 1, circuit 14-LG28 (VT/WH), wiring harness side and ground. |
| Is battery voltage measured? Yes No LOCATE and RECTIFY the break in the circuit between fuse F13 (CJB) and the reversing lamp switch using the Wiring Diagrams. CHECK the operation of the system. |
A4: CHECK THE REVERSING LAMP SWITCH |
| 1 Ignition switch in position 0. |
| 2 Connect a fused jumper wire (15 A) at the reversing lamp switch, connector C72, between pin 1, circuit 14-LG28 (VT/WH) and pin 2, circuit 14S-LG39 (VT/OG), wiring harness side. |
| 3 Ignition switch in position II. |
| 4 CHECK the reversing lamp. |
| Does the reversing lamp illuminate? Yes INSTALL A NEW reversing lamp switch. CHECK the operation of the system. No |
A5: CHECK THE GROUND CONNECTION OF THE REVERSING LAMP FOR OPEN CIRCUIT |
| 1 Ignition switch in position 0. |
| 2 Disconnect Reversing lamp from connector C41a. |
| 3 Measure the resistance between the reversing lamp, connector C41a, circuit 31-LG39 (BK), wiring harness side and ground. |
| Is less than 2 Ohm measured? Yes LOCATE and RECTIFY the break in circuits 14S-LG39(A) (VT/OG) between the reversing lamp switch and the reversing lamp using the Wiring Diagrams. CHECK and RENEW the reversing lamp as required. CHECK the operation of the system. No LOCATE and RECTIFY the break in the circuit between the reversing lamp and soldered connection S120 using the Wiring Diagrams. CHECK and RENEW the reversing lamp as required. CHECK the operation of the system. |