Removal and Installation

1. Detach the damper and lower the glove compartment.
2. Working through the glove compartment opening, detach and disconnect the temperature blend door actuator jumper harness electrical connector.
3. Detach the in-vehicle temperature sensor aspirator hose pin-type retainer from the instrument panel support.
4. Detach the instrument panel wire harness pin-type retainer from the heater core and evaporator core housing support.
5. Remove the 2 RH temperature blend door actuator screws.
6. Reposition the RH temperature blend door actuator to allow access to the electrical connector and disconnect the RH temperature blend door

actuator electrical connector.

7. Remove the RH temperature blend door actuator.
8. To install, reverse the removal procedure.