General Procedures CAUTION:Collect the refrigerant oil in a clean measuring cylinder. | -
NOTE:This step only needs to be carried out when replacing the A/C compressor. NOTE:Rotate the compressor shaft at least 6 to 8 turns when draining the refrigerant oil. Drain the refrigerant oil from the defective A/C compressor and dispose of it. | | -
CAUTION:If the refrigerant oil is not to be reused within 15 minutes of draining it from the new compressor, store it in a closed and sealed container to prevent ingress of moisture. NOTE:The refrigerant oil from the new A/C compressor needs to be drained because the fill capacities at the factory are not always the same. NOTE:Rotate the compressor shaft at least 6 to 8 turns when draining the refrigerant oil. Drain the refrigerant oil from the new A/C compressor. | | -
CAUTION:The amount of refrigerant oil topped up must not exceed the refrigerant oil fill capacity. CAUTION:If other A/C components are being renewed in addition to the A/C compressor, there is no need to top up with additional refrigerant oil, apart from filling the compressor. Add the calculated quantity of new refrigerant oil. See: Specifications (412-00 Heating, Ventilation, Air-Conditioning - General information, Specifications). | | |