Removal and Installation Two-legged puller M6 x 30 mm bolt Spacer shim Removal WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury. | -
Remove the drive plate for the stationary refrigeration compressor. | | -
Remove the belt pulley for the stationary refrigeration compressor. - Remove the distance washers.
- Remove and discard the snap ring.
| | -
NOTE:Mark the position of the connector for the stationary refrigeration clutch in relation to the compressor housing. Remove the field coil using a suitable two-legged puller. | Installation WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury. | -
NOTE:Do not skew the field coil when installing it in the stationary refrigeration compressor. Using an M6 x 30 mm bolt, a spacer shim and the compressor drive plate, install the field coil. | | -
Remove the M6 x 30 mm bolt, spacer shim and compressor drive plate. - Install the distance washers.
| | -
NOTE:Install a new belt pulley snap ring for the stationary refrigeration compressor. Install the belt pulley for the stationary refrigeration compressor. | | -
Install the drive plate for the stationary refrigeration compressor. | | |