WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury.
Push the driver's seat forwards as far as possible.
Unscrew the band clamp bolts for the stationary refrigeration pressure regulator.
Cut the cable ties.
CAUTION:Seal off the refrigerant lines and the stationary refrigeration pressure regulator to prevent dirt ingress.
Remove the stationary refrigeration pressure regulator.
Discard the O-rings.
Installation
WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury.
NOTE:Install new refrigerant line O-rings.
NOTE:Coat the O-rings for the refrigerant lines with clean refrigerant oil prior to installation.