Instrument Cluster / Carrier: Removal and Replacement

Instrument Cluster - Removal

REMOVAL

WARNING: To avoid serious or fatal injury on vehicles equipped with airbags, disable the supplemental restraint system before attempting
any steering wheel, steering column, airbag, seat belt tensioner, impact sensor, or instrument panel component diagnosis or service. Disconnect
and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to discharge before performing further
diagnosis or service. This is the only sure way to disable the supplemental restraint system. Failure to take the proper precautions could result
in accidental airbag deployment.

CAUTION: The following procedure is for replacement of an ineffective and unresponsive Instrument Cluster (IC) with a new unit. If the IC is
ineffective or damaged but still responsive, it may be replaced using an automatic replacement procedure that will upload IC parameterization
data from the existing IC to the diagnostic scan tool, then download that data to the new IC. Refer to the MISCELLANEOUS FUNCTIONS
 
menu item under the IC module in the diagnostic scan tool, then select MODULE AUTO REPLACEMENT  and follow the scan tool prompts to
replace the IC. Do not lock down the IC until all of the steps are followed and completed or the new IC may be irreversibly damaged. This procedure
initializes and configures the IC for certain optional equipment on the vehicle without the need for performing a separate cluster programming procedure.
Failure to correctly parameterize the IC prior to it being electronically locked down will result in the IC being incorrectly and irreversibly configured for
improper vehicle equipment options, which will require the IC be replaced again with another new and unused unit to resolve.

1. Disconnect and isolate the battery negative cable.
2. Adjust the steering wheel (1) downward to its lowest position.
3. Insert a trim stick or another suitable wide flat-bladed tool between the upper edge of the instrument cluster (2) lens and the underside of the

cluster bezel hood formation and pry the cluster gently and evenly outward until the integral latch (3) at each side of the cluster unsnaps from the
instrument panel.

4. Pull the cluster out from the instrument panel far enough to access and disconnect the wire harness connector (2) from the receptacle on the back

of the cluster rear cover (1).

5. Remove the instrument cluster from the instrument panel.

Instrument Cluster - Installation

INSTALLATION

WARNING: To avoid serious or fatal injury on vehicles equipped with airbags, disable the supplemental restraint system before attempting
any steering wheel, steering column, airbag, seat belt tensioner, impact sensor, or instrument panel component diagnosis or service. Disconnect
and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to discharge before performing further
diagnosis or service. This is the only sure way to disable the supplemental restraint system. Failure to take the proper precautions could result

Removal and Replacement|Page 2120 > < Symptom Related Diagnostic Procedures|Page 2117