2. Disconnect the 23P connector from the power window master switch.
3. Inspect the connector and socket terminals to be sure they are all making good contact.
-
If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
-
If the terminals look OK, go to step 4.
4. With the door multiplex control unit still disconnected, make these input tests at the connector.
-
If any test indicates a problem, find and correct the cause, then recheck the system.
-
If all the input tests prove OK, the door multiplex control unit must be faulty, replace the power window master switch.
Gauge Control Module Input Test
Gauge Control Module Input Test
1. Remove the gauge control module.
2. Disconnect the 30P connector from the gauge control module.
3. Inspect the connector and socket terminals to be sure they are all making good contact.
-
If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
-
If the terminals look OK, go to step 4.