Accord EX Coupe V6-3.0L (2001)
Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor Circuit Troubleshooting
Climate Control
Recirculation Control Motor Circuit Troubleshooting
1. Check the No.3 (7.5 A) fuse in the driver's under-dash fuse/relay box.
Is the fuses OK?
YES - Go to step 2.
NO - Replace the fuse, and recheck.
2. Disconnect the recirculation control motor 7P connector.
3. Turn the ignition switch ON (II).
4. Measure the voltage between the No.1 terminal of the recirculation control motor 7P connector and body ground.
Is there battery voltage?
YES - Go to step 5.
NO - Repair open in the wire between the recirculation control motor and the No.3 fuse in the driver's under-dash fuse/relay box.
5. Turn the ignition switch OFF.
6. Test the recirculation control motor. Is the recirculation control motor OK?
YES - Go to step 7.
NO - Go to step 11.
7. Disconnect the climate control unit 20P connector.
8. Check for continuity between the No.3 and No.4 terminals of the climate control unit 20P connector and body ground individually.
Is there continuity?