CRX Si L4-1590cc 1.6L SOHC (D16A6) MFI (1988)
-
Check resistance of the field coil:
Field Coil Resistance: 3.58 ± 0.15 ohm at 20°C (68°F)
If resistance is not within specifications replace the coil.
-
Measure the clearance between the rotor pulley and armature plate all the way around.
If the clearance is not within specified limits the pressure plate must be removed and shims added or removed as required.
CLEARANCE: 0.35 - 0.65 mm (0.014 - 0.026 in)
NOTE: The shims are available in four sizes: 0.1 mm, 0.2 mm, 0.4 mm and 0.5 mm of thickness.