CLUTCH HUB AND INSERT CLEARANCE 

Use a thickness gauge to measure the clearance between the clutch hub and the insert. If the measured value exceeds the specified limit, the clutch
hub and the insert must be replaced.
-

3rd-4th

Standard 0.01-0.19 (0.0004-0.0075).
Limit 0.3 (0.012).

-

1st-2nd/5th

Standard 0.09-0.31 (0.0035-0.0122).
Limit 0.4 (0.016).

MAINSHAFT RUN-OUT 

Install the mainshaft to V-blocks. Use a dial indicator to measure the mainshaft central portion run-out. If the measured mainshaft run-out exceeds
the specified limit, the mainshaft must be replaced. Mainshaft run-out Limit 0.05 mm (0.0020 inch).

GEAR INSIDE DIAMETER 

Use an inside dial indicator to measure the gear inside diameter. If the measured value is less than the specified limit, the gear must be replaced.
Gear inside diameter:
-

1st/3rd

Standard 45.000-45.013 mm (1.771 -1.772 inch).
Limit 45.100 mm (1.776 inch).

-

2nd

Standard 52.000-52.013 mm (2.047-2.048 inch).
Limit 52.100 mm (2.051 inch).