honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Fan Motor Testing|Page 2071 > < Fan Motor Testing|Page 2069
Page 4
background image

6. Check for continuity between fan control module 8P connector terminal No. 4 and body ground.

Is there continuity?
YES - Replace the fan control module and if the radiator fan does not run, replace the fan itself.
NO - Repair an open in the wire between fan control module terminal No. 4 and G401.

Troubleshooting C

Troubleshooting C

NOTE:  Refer to the symptom troubleshooting index before troubleshooting.

1. Disconnect the fan control relay.
2. Disconnect the radiator fan motor 2P connector.

3. Check for continuity between fan control relay 5P connector terminal No. 4 and radiator fan motor 2P connector terminal No. 2.

Is there continuity?
YES - Go to step 4.
NO - Repair an open in the wire between fan control relay 5P connector terminal No. 4 and radiator fan motor 2P connector terminal No. 2. 

4. Remove the condenser fan relay from the underhood fuse/relay box.
5. Disconnect the radiator fan switch A 2P connector.

6. Check for continuity between condenser fan relay 4P connector terminal No. 4 and radiator fan switch A 2P connector terminal No. 2.

Is there continuity?
YES - Go to step 7.
NO - Repair an open in the wire between condenser fan relay 4P connector terminal No. 4 and radiator fan switch A 2P connector terminal No. 2. 

7. Install the condenser fan relay and fan control relay, and connect the radiator fan motor 2P connector.

Fan Motor Testing|Page 2071 > < Fan Motor Testing|Page 2069