H2 V8-6.2L (2008)
Notice: Refer to Fastener Notice .
5. Connect the evaporator tube at the fitting.
Tighten the fitting to 25 N.m (18 lb ft).
6. Evacuate and recharge the system. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Refrigerant Recovery and Recharging)
.
7. Leak test the fittings of the repaired component using J 39400-A .