H2 V8-6.2L (2008)
Washer Fluid Level Switch: Service and Repair
Washer Solvent Container Level Sensor Replacement
Removal Procedure
1. Open the hood.
2. Remove the washer solvent from the washer solvent container.
3. Disconnect the washer solvent level sensor (6) electrical connector.
4. Remove the A/C low pressure switch. Refer to Air Conditioning (A/C) Low Pressure Switch Replacement (See: Sensors and Switches -
HVAC/Refrigerant Pressure Sensor / Switch/Service and Repair/Air Conditioning (A/C) Low Pressure Switch Replacement) .
5. Mark the location of the sensor prior to removal.
Important: The level sensor arm hinges at the point called out (1). Before servicing the level sensor, it is necessary to get the level sensor
arm in a horizontal position. Failure to do so will result in breakage of the level sensor.
6. Get the level sensor in a horizontal position by inserting a long, narrow tool through the washer solvent fill hole, and gently raising the sensor arm.
7. Remove the level sensor from the washer solvent container.
Installation Procedure