H3 L5-3.7L (2007)

5. While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a
terminal out of a connector.
Repair Procedure
Use the appropriate terminal and follow the instructions in the J-38125.
Location of the terminal in the repair tray and the proper crimp tool can be found in the appropriate connector end view.
Kostal Connectors
Kostal Connectors
Tools Required
J-38125 Terminal Repair Kit
Removal Procedure