hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Charging System - Diagnosis|Page 1332 > < Charging System - Diagnosis|Page 1330
Page 12
background image

i)

Circuit Resistance Test:

1.

Set TEST SELECTOR knob to # 2 CHARGING position.

2.

Set LOAD INCREASE knob to the OFF position.

3.

Set VOLT SELECTOR knob to the EXT 18 V position.

4.

Connect tester leads as shown in the figures.

5.

Start the engine and increase to 2000 RPM.

6.

Adjust LOAD INCREASE knob until the reading of the Red Ammeter Scale indicates 175 A.

7.

Observe the reading on the Green Voltmeter Scale. Note this reading.

8.

Set VOLT SELECTOR knob to INT 18 V position. Observe the reading on the Green Voltmeter Scale. Subtract this reading from the
reading obtained in step 7. The difference is the voltage drop caused by circuit resistance and must be less than 0.5 volts.

NOTE:

If the voltage drop exceeds 0.5 volts, then conduct the test on the following page (Insulated Circuit Resistance Test).

ii)

Insulated Circuit Resistance Test:

NOTE:

Leave main clamps on VAT-40.

Charging System - Diagnosis|Page 1332 > < Charging System - Diagnosis|Page 1330