isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection > < Dual Pressure Switch|Page 4849
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation
Triple Pressure Switch

TRIPLE PRESSURE SWITCH

Triple pressure switch (2) is installed on the upper part of the receiver/drier. This switch is constructed with a unitized type of two switches. One of them
is a low and high pressure switch (Dual pressure switch) to switch ON or OFF the magnetic clutch as a result of irregularly high-pressure or low pressure
of the refrigerant. The other one is a medium pressure switch (Cycling switch) to switch ON or OFF the condenser tan sensing the condenser high side
pressure.

Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection > < Dual Pressure Switch|Page 4849