Ascender 4WD L6-4.2L (2003)

Battery Cable: All Technical Service Bulletins
Electrical - Intermittent No Crank/No Start Condition
TSB SB06-04-S003
Intermittent No Crank, No Start
ISSUE DATE: APRIL 2006
Affected Vehicles
2003-2007 Isuzu Ascender (US/UT)
Service Information
Condition:
Some customers may comment on an intermittent no crank, no start condition.
Possible Cause:
This condition may be due to poor battery cable connections. Cross-threaded/stripped battery cable bolts inside the battery side post terminals may cause
poor battery cable connections.
Correction:
Clean battery side terminal stripped threads, replace battery cable bolt.
Service Procedure
To avoid replacing the battery, do the following steps:
^
Clean the threads in the battery side post terminals using a 3/8" (# 16) A/C bottom tap.
^
If the battery cable bolt is damaged then replace.
The battery cable bolt 8-19115-561-0 is serviced separately from the cable and is available from AIPDN. Be sure to use the correct bolt.
Parts Information
Warranty Claim Information
Use the labor operation shown.
NOTE:
1.
Labor Time includes administrative time allowance.