Battery Cable: All Technical Service Bulletins
Electrical - Intermittent No Crank/No Start Condition

TSB SB06-04-S003

Intermittent No Crank, No Start

ISSUE DATE: APRIL 2006

Affected Vehicles

2003-2007 Isuzu Ascender (US/UT)

Service Information

Condition:
Some customers may comment on an intermittent no crank, no start condition.

Possible Cause: 
This condition may be due to poor battery cable connections. Cross-threaded/stripped battery cable bolts inside the battery side post terminals may cause
poor battery cable connections.

Correction:
Clean battery side terminal stripped threads, replace battery cable bolt.

Service Procedure

To avoid replacing the battery, do the following steps:

^

Clean the threads in the battery side post terminals using a 3/8" (# 16) A/C bottom tap.

^

If the battery cable bolt is damaged then replace.

The battery cable bolt 8-19115-561-0 is serviced separately from the cable and is available from AIPDN. Be sure to use the correct bolt.

Parts Information

Warranty Claim Information

Use the labor operation shown.

NOTE: