01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Isuzu Axiom 2WD V6-3.5L (2002)03 · Maintenance
03 · Maintenance

Refrigerant: Specifications (page 2 of 5)

Make
Isuzu
Model
Axiom 2WD
Engine
V6-3.5L
Year
2002
Section
Fluids › Refrigerant
MaintenanceSpecifications · page 2 of 5
background image

Refrigerant: Testing and Inspection

General Repair Procedure

Precautions For Replacement or Repair of Air Conditioning Parts

There are certain procedures, practices and precautions that should be followed when servicing air conditioning systems:

-

Keep your work area clean.

-

Always wear safety goggles and protective gloves when working on refrigerant systems.

-

Beware of the danger of carbon monoxide fumes caused by running the engine.

-

Beware of discharged refrigerant in enclosed or improperly ventilated garages.

-

Always disconnect the negative battery cable and discharge and recover the refrigerant whenever repairing the air conditioning system.

-

When discharging and recovering the refrigerant, do not allow refrigerant to discharge too fast; it will draw compressor oil out of the system.

-

Keep moisture and contaminants out of the system. When disconnecting or removing any lines or parts, use plugs or caps to close the fittings
immediately
Never remove the caps or plugs until the lines or parts are reconnected or installed.

-

When disconnecting or reconnecting the lines, use two wrenches to support the line fitting, to prevent from twisting or other damage.

-

Always install new O-rings whenever a connection is disassembled.

-

Before connecting any hoses or lines, apply new specified compressor oil to the O-rings.

-

When removing and replacing any parts which require discharging the refrigerant circuit, the operations described in this section must be
performed in the following sequence:
1. Use the J-39500 (ACR(4): HFC-134a Refrigerant Recovery / Recycling / Recharging / System) or equivalent to thoroughly discharge and

recover the refrigerant.

2. Remove and replace the defective part.
3. After evacuation, charge the air conditioning system and check for leaks.

Repair Of Refrigerant Leaks

Refrigerant Line Connections

Install new O-rings, if required. When disconnecting or connecting lines, use two wrenches to prevent the connecting portion from twisting or becoming
damaged.

When connecting the refrigerant line at a block joint, securely insert the projecting portion of the joint portion into the connecting hole on the unit side
and secure with a bolt. Apply the specified compressor oil to the O-rings prior to connecting.

CAUTION:  Compressor (PAG) oil to be used varies according to the compressor model. Be sure to apply oil specified for the model of compressor.