isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Starter Motor|Removal and Installation|Page 2656 > < Electrical Specifications|Page 2653
Page 1
background image

Starter Motor: Service and Repair
Removal and Installation

REMOVAL

1. Battery ground cable.
2. Disconnect Heated O2 Sensor connector (1).

3. Remove exhaust front left pipe (2).
4. Disconnect starter wiring connector from terminals "30" (1) and "50" (2).
5. Remove starter assembly mounting bolts on inside and outside (3).

6. Remove starter assembly (4) toward the bottom of engine.

INSTALLATION

1. Install starter assembly(4).
2. Install mounting bolts and tighten bolts to specified torque (3).

Torque: 40 Nm (30 lb-ft)