isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Hydraulic Control Assembly - Antilock Brakes > < Combination Valve|Page 4518
Page 2
background image

Tighten
Tighten brake pipe fittings to 17 N.m (13 lb ft).

5. Connect the combination valve electrical connector (10).

Important: Verify that the combination valve metering rod is depressed during bleeding.

6.  Bleed the brake system. 

Hydraulic Control Assembly - Antilock Brakes > < Combination Valve|Page 4518