isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Water Pump > < Thermostat, Engine Cooling|Specifications|Page 1950
Page 2
background image

9. Clean the sealing surface on the lower intake manifold.

Installation Procedure 

Important:  In order to prevent leakage, thoroughly clean all parts and sealing surfaces.

1. Install the coolant thermostat in the lower intake manifold

2. Install a new gasket (if used). Otherwise, place a 3 mm (1/8 in) bead of RTV sealer) at the groove on the coolant outlet sealing surface.
3. Install the coolant outlet on the lower intake manifold.

4. Install the attaching bolts. 

Tighten coolant outlet bolts to 19 N.m (14 lb ft).

5. Install the radiator inlet hose.
6. Fill the cooling system with specified coolant and concentration. 
7. Inspect all sealing surfaces for leaks after starting the engine. 

Water Pump > < Thermostat, Engine Cooling|Specifications|Page 1950