isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Air Door, HVAC > < Component Locations|Page 5261
Page 2
background image

1. Install the accumulator into the accumulator clamp.

NOTE:  Refer to Fastener Note in Service Precautions.

2. Install the accumulator clamp bolt.

Tighten
Tighten the accumulator clamp bolt to 10 N.m (8 lb ft)

3. Install new O-ring seals.
4. Install the compressor and condenser hose assembly to the accumulator. 

Tighten
Tighten the compressor and condenser hose to 41 N.m (30 lb ft).

5. Install the evaporator and accumulator hose to the accumulator.
6. Connect the electrical connectors to the pressure cycling switch.
7. Connect the negative battery cable.
8. Add refrigerant to the system.
9. Inspect the system for leaks.

Air Door, HVAC > < Component Locations|Page 5261