isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Description and Operation
Page 1
background image

Condenser HVAC: Service and Repair

Removal Procedure

1. Recover the refrigerant from the system.
2. Remove the upper fan shroud.
3. Remove the radiator.
4. Remove the compressor and condenser hose assembly from the condenser.
5. Remove the evaporator tube from the condenser.

6. Remove the insulator retainer bolts and the upper insulator retainers.
7. Remove the condenser.

Installation Procedure

1. Install the condenser.

NOTE:  Refer to Fastener Note in Service Precautions.

2. Install the upper insulator retainers and the insulator retainer bolts. 

Tighten
Tighten the bolts to 2.4 N.m (21 lb in).

3. Install the evaporator tube to the condenser.
4. Install the compressor and condenser hose assembly to the condenser. 
5. Install the radiator.
6. Install the upper fan shroud.
7. Add refrigerant to the system.
8. Inspect the system for leaks.

Control Assembly, HVAC > < Condenser HVAC|Description and Operation