Hose/Line HVAC: Service and Repair
Removal and Installation

Compressor And Condenser Hose

Removal Procedure

CAUTION:  Refer to Battery Disconnect Caution in Service Precautions.

1. Disconnect the battery negative cable.
2. Recover the refrigerant from the system.

3. Remove the compressor and condenser hose bolt and the washer.
4. Remove the compressor and condenser hose from the compressor.
5. Remove the sealing washers.

6. Remove the compressor and condenser hose from the accumulator.
7. Remove the O-ring seal.