isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 5479 > < Leak Check - Repair of Refrigerant Leaks|Page 5477
Page 3
background image

4. Install the compressor and condenser hose to the accumulator.

Tighten
Tighten the hose to 41 N.m (30 lb ft).

5. Install the sealing washers.
6. Install the compressor and condenser hose to the compressor.

7. Install the compressor and condenser hose washer and the bolt.

Tighten
Tighten the bolt to 33 N.m (24 lb ft).

8. Connect the battery negative cable.
9. Add refrigerant to the system.

10. Inspect the system for leaks.

Evaporator and Accumulator Hose

Evaporator and Accumulator Hose Assembly

Removal Procedure

CAUTION:  Refer to Battery Disconnect Caution in Service Precautions.

1. Disconnect the negative battery cable.
2. Recover the refrigerant from the system.
3. Remove the evaporator and accumulator hose from the evaporator.
4. Remove the O-ring seal.

Leak Check - Repair of Refrigerant Leaks|Page 5479 > < Leak Check - Repair of Refrigerant Leaks|Page 5477