isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6409 > < Diagram Information and Instructions|Page 6407
Page 19
background image

1. Remove the outer jacket (1). Use care not to cut into the drain wire of the mylar tape.
2. Unwrap the tape. Do not remove the tape. Use the tape in order to rewrap the twisted conductors after the splice is made.

3. Prepare the splice. Untwist the conductors and follow the splicing instructions for copper wire. Staggering the splices by 65 mm is recommended.

4. Re-assemble the cable.

-

Rewrap the conductors with the mylar tape.

Diagram Information and Instructions|Page 6409 > < Diagram Information and Instructions|Page 6407