isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6732 > < Diagram Information and Instructions|Page 6730
Page 22
background image

-

Insert the wire into the splice sleeve barrel until it hits the barrel stop.

-

Close the handles of the crimp tool tightly until the crimper handles open when released. The crimper handles will not open until you apply the
proper amount of pressure to the splice sleeve. Repeat steps 4 and 5 for the opposite end of the splice.

8. Shrink the insulation around the splice.

-

Using the heat torch apply heat to the crimped area of the barrel.

-

Gradually move the heat barrel to the open end of the tubing.
-

The tubing will shrink completely as the heat is moved along the insulation.

-

A small amount of sealant will come out of the end of the tubing when sufficient shrinkage is achieved.

Flat Wire Repairs

NOTE:  Be careful when you repair the flat wire within the flex wiring harness. External material of the flex wiring harness is Mylar Reg. This material
can not be easily removed without damaging the flat wire.
The flat wire within the flex wiring harness is not serviceable.If an open or short exists within the flex wiring harness the complete harness must be
replaced.

Diagram Information and Instructions|Page 6732 > < Diagram Information and Instructions|Page 6730