isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Fuel Strainer <--> [Fuel Pump Pickup Filter]|Description and Operation|Page 1239 > < Fuel Strainer <--> [Fuel Pump Pickup Filter]|Description and Operation
Page 1
background image

Fuel Strainer: Service and Repair

Removal Procedure

Tools Required

-

J 34730-1A Fuel Pressure Gauge

-

J 39765 Fuel Sender Lock Nut Wrench

CAUTION:  Refer to Battery Disconnect Caution in Service Precautions.

1. Disconnect the negative battery cable.
2. Relieve the fuel system pressure.
3. Drain the fuel tank.
4. Remove the fuel tank.
5. Remove the fuel sender assembly. 
6. Note the position of the fuel strainer (2) on the fuel sender.
7. Support the fuel sender assembly with one hand and grasp the strainer (2) with the other hand.
8. Pull the strainer off the fuel sender. Discard the strainer after inspection.
9. Inspect the strainer. Replace a contaminated strainer and clean the fuel tank.

Installation Procedure

1. Install a new fuel strainer (2) in the same position as noted during disassembly. Push the strainer on the bottom of the fuel sender until the strainer

is fully seated.

2. Install the fuel sender assembly.
3. Install the fuel tank. 
4. Refill the fuel tank.
5. Install the fuel filler cap.
6. Connect the negative battery cable.

Fuel Strainer <--> [Fuel Pump Pickup Filter]|Description and Operation|Page 1239 > < Fuel Strainer <--> [Fuel Pump Pickup Filter]|Description and Operation