isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 1284 > < Leak Check - Repair of Refrigerant Leaks|Page 1282
Page 2
background image

8. Remove the compressor and condenser hose from the condenser.
9. Remove the O-ring seal.

Installation Procedure

1. Install a new O-ring seal.

Coat the O-ring seal with 525 viscosity refrigerant oil.

NOTE:  Refer to Fastener Note in Service Precautions.

2. Install the compressor and condenser hose to the condenser. 

Tighten
Tighten the hose to 24 N.m (18 lb ft).

3. Install a new O-ring seal.

Coat the O-ring with 525 viscosity refrigerant oil.

Leak Check - Repair of Refrigerant Leaks|Page 1284 > < Leak Check - Repair of Refrigerant Leaks|Page 1282