isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2539 > < Initial Inspection and Diagnostic Overview|Page 2537
Page 10
background image

Outputs

Chime

Range: NONE/HEADLAMP/KEY IN IGNITION/SEAT BELT/TURN SIGNAL

The chime output refers to the commanded state of the audible chime.

NONE displays when no audible chime sound is commanded.

HEADLAMP displays when the headlamp ON reminder feature commands the chime to turn ON.

KEY IN IGNITION displays when the key in ignition reminder feature and the driver door open feature command the chime to turn ON.

SEAT BELT displays when the driver seat belt not buckled reminder feature commands the chime to turn ON.

TURN SIGNAL displays when the turn signal ON reminder feature (on for more than 0.75 mile) commands the chime to turn ON.

Interior Lighting Mode

Range: NON E/INTERIOR/ILLUM ENTRY/EXIT LIGHTING/REMOTE ILLUM

The interior lighting mode output displays the name of the feature that is commanding the interior lights to turn ON.

NONE displays when the interior lights are not commanded to turn ON.

INTERIOR displays when the dome lamp switch commands the interior lights to turn ON.

ILLUM, ENTRY, EXIT LIGHTING, REMOTE ILLUM. display when the respective mode commands the interior lighting to turn ON.

Inadvertent Power Relay

Range: ON/OFF

The inadvertent power relay output refers to the commanded state of the inadvertent power relay coil.

ON displays when the BCM commands the inadvertent power relay coil to energize. The command allows the relay to power up the following
components:

-

The courtesy lamp relay

-

The vanity lamps

-

The underhood lamps

-

The glove box lamp

OFF displays when the BCM does not command the inadvertent power relay coil to turn ON. The inadvertent power relay coil then does not allow
current to the following components:

-

The courtesy lamp relay

-

The vanity lamps

-

The underhood lamp

-

The glove box lamp

RAP Relay

Range: ON/OFF

The RAP relay output refers to the commanded state of the RAP relay coil.

ON displays when the BCM commands the RAP relay coil to energize. The command allows the relay to power up the following components:

-

The radio

-

The power windows

OFF displays when the BCM commands the RAP relay to turn OFF.

Headlamp Power Relay

Range: ON/OFF

Initial Inspection and Diagnostic Overview|Page 2539 > < Initial Inspection and Diagnostic Overview|Page 2537