Page 3
background image

Insert the retaining bolts through the EGR valve and gasket into the mounting holes.

Tighten
First tighten the bolts to 10 N.m (89 lb in), and then tighten the bolts to 25 N.m (18 lb ft).

4. Connect the EGR valve electrical connector.
5. Connect the negative battery cable.