13.

Obtain a nitrogen tank, close the valve (2) on the tank, and remove the regulator assembly. (Figure 5)

14.

Install the J 44466-10 (5) to the nitrogen tank(3). The J 44466-10 regulator is preset to 150 psi. (Figure 5)

15.

Connect the J 44466-10 hose (1) to the J 44466-12(3). (Figure 6)

16.

Install the J 39021 Injector/Coil Balance Tester, the J 39021-210 Injector Tester Adapter Box, and J 39021-301 V6 Fuel Injector Test Adapter (1)
to the metering body electrical connector.

17.

Adjust the amperage selector switch on J 39021 to 0.5 amps.

18.

Open the valve (2) on the nitrogen tank (3). (Figure 7)

19.

Open the valve (4) on the J 44466-10 to pressurize the fuel system. The minimum pressure required on the gauge (6) is 150 psi. If 150 psi is not
obtained, the tank (3) must be refilled prior to performing this procedure. (Figure 7)

20.

Close the valve (4) on the J 44466-10. (Figure 7)

21.

Energize one injector using the J 39021. Observe a pressure drop on the gauge (6) and verify the injector/poppet valve operation. An
injector/poppet that is "stuck" and not operational will have no pressure drop on the gauge. If an injector remains "stuck" repeat the procedure
multiple times (as required) until the injector is operational.