Ignition Control Module: Service and Repair

Removal Procedure

1. Remove the air cleaner assembly (2) and nut (1). 
2. Disconnect the electrical connectors.
3. Remove the ignition coil wire to the distributor.

4. Remove the studs holding the bracket and the ignition coil to the intake manifold.
5. Remove the bracket and the ignition coil.
6. Drill and punch out the two rivets holding the ignition coil to the bracket.
7. Remove the ignition coil from the bracket.

Installation Procedure

A replacement ignition coil kit comes with two screws in order to attach the ignition coil to the bracket.

1. Install the ignition coil to the bracket with the two screws.

NOTE:  Refer to Fastener Note in Service Precautions.