background image

signal circuit.

The following actions will occur if there is an open or a short to ground in the ambient light sensor circuit:

-

The scan tool will display DARK.

-

The BCM will default into a DARK state and turn the headlamps ON.

If the head lamps are set to the AUTO position while in the LIGHT state and the ambient light level conditions change to DARK for 15 seconds, the 
BCM will turn the headlamps ON.

If the headlamps are set to the AUTO position while the DARK state and the ambient light level conditions change to LIGHT for 20 seconds, the BCM
will turn the headlamps OFF.

Dusk

YES/NO
The displayed value refers to the dimming signal output from the BCM.This information is used by the BCM for the operation of the following features:

-

Automatic headlamp

-

Daytime running lamps (DRL) feature 

Dusk is displayed whenever the park lamps are ON.

High Beam Input

Range: 0.0 - 18.0 Volts

The BCM uses this input in order to determine the state of the High beam headlamps. The BCM measures the circuit voltage at a point between both of
the High beam headlamps and the beam selector switch. The High beam input voltage will vary depending on the state of the headlamps.

Refer to the table.

Vehicle Speed

Range: 0 - 205 km/h (0 - 127 mph)

The BCM uses the data for determining how fast the vehicle is traveling. The BCM uses this data for the operation of the following features:

-

Automatic door lock feature

-

Turn signal reminder feature

Inadvertent Power Timer

Range: 0 - 1216 seconds

The BCM uses this feature to protect the battery against inadvertent battery rundown caused by devices that attach to the courtesy lamp circuit. If the
following lights remain ON, the BCM will turn the lights OFF after 20 minutes:

-

The dome/courtesy lamp

-

The vanity lamp

-

The underhood or the glove box lamp

The lights are turned OFF by the inadvertent power relay. The inadvertent power relay supplies power to the courtesy lamp circuit when the ignition is in
the OFF position. The number of seconds displayed refers to the amount of time left before the BCM will turn the relay OFF.

RAP Timer

Range: 0 - 1198 seconds

The BCM uses this feature to control the devices that attach to the retained accessory power (RAP) circuit. This feature allows the operation of the
following components for 20 minutes after the ignition key is turned to the OFF position and before any door is opened:

-

The radio

-

The power windows

When any door is opened or after 20 minutes, the BCM opens the ground circuit for the RAP relay. The following components will turn OFF: