Page 6
background image

Steps 17 - 22

Test Description

The numbers below refer to the step numbers on the diagnostic table:

2. This test determines whether the malfunction is in the supplemental restraint sensing and diagnostic module (SDM) circuitry or in the instrument

cluster power feed circuitry.

3. This test determines whether voltage is present in the warning lamp circuit.
4. This test isolates CKT 358 and inspects for a short in CKT 358 to B+.
6. This test determines if the malfunction is in the instrument cluster connector.
8. This test determines if the open is due to a bad instrument cluster or an open in the warning lamp circuitry.
11. This test inspects whether power is available to the instrument cluster power feed circuit.
12. This test inspects for a short from the instrument cluster power feed circuit to ground.
13. This test determines whether the short to ground is due to a short in the wiring or internal to the instrument cluster.
17. This test determines if the malfunction is in the instrument cluster connector.
19. This test determines whether the malfunction is due to an open power feed circuit from the GAUGES Fuse.