Shift Solenoid: Description and Operation
3-2 Shift Solenoid Valve Assembly

3-2 Shift Solenoid Valve Assembly

Important: The 3-2 shift solenoid valve assembly resistance should be a minimum of 20-24 ohms at 20°C (68°F).

The 3-2 shift solenoid valve assembly is an ON/OFF solenoid that is used in order to improve the 3-2 downshift. The solenoid regulates the release of
the 3-4 clutch and the 2-4 band apply.
If a voltage fault is detected in the 3-2 shift solenoid circuit, diagnostic trouble code P0785 will set.

1-2 and 2-3 Shift Solenoid Valves|Page 3741 > < 1-2 and 2-3 Shift Solenoid Valves