isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Ignition Control Module > < Ignition Coil|Locations|Page 2969
Page 1
background image

Ignition Coil: Testing and Inspection

1. Turn OFF the ignition switch.
2. Disconnect the distributor lead and wiring from the ignition coil.

Ignition Coil Test

NOTE: Do not insert the J 39200 digital multimeter probe into the ignition coil connectors. The female terminals could be deformed, resulting in
intermittent operation. Only make contact with the front edge of the terminals.

3. Connect an ohmmeter as shown.

-

Use the high scale.

-

If the reading is not infinite, replace the coil. 

Ignition Coil Test

4. Connect an ohmmeter as shown.

-

Use the low scale.

-

If the reading is not 0.1 ohms, replace the coil. 

5. Connect an ohmmeter as shown.

-

Use the high scale.

-

If the reading is not 5-25 kohms, replace the coil.

6. Reconnect the distributor lead and wiring to the coil.

Ignition Control Module > < Ignition Coil|Locations|Page 2969