isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Relays and Modules - Starting and Charging > < Initial Inspection and Diagnostic Overview|Page 147
Page 2
background image

Supl Rst Diagnostic Energy Reserve Module

1. Connect the DERM electrical connector to the DERM.
2. Connect the connector lock.

Supl Rst Diagnostic Energy Reserve Module

3. Install the DERM to the mounting bracket. 
Tighten
Tighten nuts to 3 N.m (25 lb in). Tighten screws 1 N.m (5 lb in).
4. Install the right hand cowl kick panel. Refer to Cowl klick Panel Trim Replacement in Interior Trim.
5. Connect the right hand sill plate. Refer to Sill Plate Replacement in Interior Trim.
6. Connect the right hand sound insulator. Refer to Instrument Panel Replacement in Interior Trim.
7. Enable the Supplemental Restraint System (SRS). Refer to Enabling the SRS.

Relays and Modules - Starting and Charging > < Initial Inspection and Diagnostic Overview|Page 147