isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|HD6/HT6|Page 232
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair
V5

Remove or Disconnect

1. Recover refrigerant using J 39500
2. Disconnect the electrical connector from the switch in the rear bead of the compressor.
3. Remove the switch retaining ring, using J 5403 internal snap ring pliers.
4. Remove switch from compressor.
5. Remove old O-ring seal from switch cavity using J 955341 O-ring removal tool or equivalent.

NOTE:  If existing switch will be reinstalled in compressor, a new O-ring seal must be used and preferably a new retainer ring should also be
used. A new switch kit has the O-ring and retainer ring included.

Install or Connect

1. Check switch cavity and O-ring groove in the rear head for dirt or foreign material and clean as necessary. Install new O-ring coated with clean

525 viscosity refrigerant oil into groove in switch cavity.

2. Lubricate the switch housing with clean 525 viscosity refrigerant oil and carefully insert switch into switch cavity until switch "bottoms" in cavity.
3. Using J 5403 snap ring pliers, install switch retaining ring with high point of curved sides adjacent to the switch housing. Be sure retaining ring is

properly seated in the switch cavity retainer ring groove.

4. Evacuate and recharge the system.
5. Leak test.

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|HD6/HT6|Page 232