isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

MIL ON - A/T Stuck In 3rd/Instrument Cluster Inoperative|Page 616 > < MIL ON - A/T Stuck In 3rd/Instrument Cluster Inoperative|Page 610
Page 1
background image

Ignition Switch: All Technical Service Bulletins
MIL ON - A/T Stuck In 3rd/Instrument Cluster Inoperative

BULLETIN NUMBER:
SB01-04-S002

ISSUE DATE:
AUGUST 2001

GROUP:
ELECTRICAL

MALFUNCTION INDICATOR LAMP (MIL) ON,
TRANSMISSION STUCK IN THIRD GEAR,
INSTRUMENT CLUSTER INOPERATIVE (Replace Ignition Switch)

AFFECTED VEHICLES

1997 - 2000 Hombre pickup with 4L60-E Automatic Transmission

SERVICE INFORMATION

Condition:

Some customers may comment on one or more of the following conditions:

The Malfunction Indicator Lamp (MIL) is ON.

The transmission is stuck in third gear.

The instrument cluster is inoperative.

Upon investigation, one or all of the diagnostic trouble codes (DTCs) P0740, P0753, P0758, P0785, and P1860 may be set.

Possible Cause:

The most likely cause of this condition may be a loss of power to the transmission on circuit 1020. This loss of power may be caused by an open in the 
ignition switch. This condition may also be the result of an incorrect installation of an aftermarket electronic device such as a remote starter or alarm
system.

Correction:

Follow the procedures in this bulletin for diagnosing if battery voltage is present at the fuse listed in the chart in step 1. Then follow the service
procedures for diagnosing fault and repair as needed.

1.

With the ignition switch in the RUN position, test for battery voltage at the appropriate fuse listed.

2.

If battery voltage is present at the fuse, inspect circuit 1020 between the fuse and the transmission for possible opens. If battery voltage is not
present at the fuse, replace the ignition switch using the ignition switch replacement procedure in the Steering Wheel and Column sub-section of
the applicable Service Manual.

3.

If the vehicle is equipped with an aftermarket electronic device (i.e., alarm or remote starter) and the DTCs are being set when the device is being
used, verify that the appropriate fuse listed above is being supplied battery voltage during operation. If voltage is not present at this fuse, these
DTCs will be set due to lack of power at the solenoids. This condition is most likely to occur with an incorrectly installed remote starting system.
If this is the case, refer the customer to the installer of the system for corrections.

MIL ON - A/T Stuck In 3rd/Instrument Cluster Inoperative|Page 616 > < MIL ON - A/T Stuck In 3rd/Instrument Cluster Inoperative|Page 610