Positive Crankcase Ventilation: Description and Operation

Crankcase Ventilation System Purpose/Operation

A crankcase ventilation system is used to provide scavenging of the crankcase vapors. Blow-by gases are passed through a crankcase ventilation oil/air
separator into the air cleaner outlet resonator. The oil/air separator is inside the valve rocker arm cover and allows any scavenged oil to be returned to the
crankcase.

The only flow through the oil/air separator is the combustion blow-by, as there is no fresh air inlet to the crankcase. The primary flow of blow-by into the
separator is through the openings inside the valve rocker arm cover. The oil/air separator causes oil, which may be suspended in the blow-by gases, to be
separated and drain back to the crankcase. The blow-by gases are then drawn into the air cleaner  outlet resonator by normal engine vacuum and burned
in the combustion process.