Twisted/shielded cable is sometimes used to protect wiring from electrical noise (stray signals). For example, the two-conductor cable of this
construction is used between the ECM and the distributor.

Step 1: Remove Outer Jacket

Remove the outer jacket and discard it. Be careful to avoid cutting into the drain wire or the mylar tape.

Step 2: Unwrap the Tape

Unwrap the mylar tape, but do not remove it. The tape will be used to rewrap the twisted conductors after the splices have been made.

Step 3: Prepare the Splice

Untwist the conductors. Then, prepare the splice by following the splicing instructions for copper wire presented earlier. Remember to stagger splices to
avoid shorts.

Step 4: Reassemble the Cable

After you have spliced and taped each wire, rewrap the conductors with the mylar tape. Be careful to avoid wrapping the drain wire in the tape.

Next, splice the drain (ground) wire following the splicing instructions for copper wire. Then, wrap the drain wire around the conductors and mylar tape.

Step 5: Tape the Cable

Tape over the entire cable using a winding motion. This tape will replace the section of the jacket you removed to make the repair.