Evaporator Drain Tube: Service and Repair

Evaporator Tube Replacement (LLV - 2.9L, LLR - 3.7L)

Tools Required

J 39400-A Halogen Leak Detector

Removal Procedure

1. Recover the refrigerant from the system. Refer to Refrigerant Recovery and Recharging (Non HP2)  (See: Service and Repair/Refrigerant

Recovery and Recharging (Non HP2)) .

2. Remove the evaporator tube nut (1) from the TXV stud.
3. Remove the evaporator tube (2) from the TXV.