i-350 L5-3.5L (2006)
2. Install the 2 fasteners retaining the PSIR bracket to the I/P structure.
Tighten the fasteners to 9 N.m (80 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the I/P assembly.
4. Position the PSIR inflator module to the front of the I/P and connect the electrical connector.
5. Connect the CPA.
6. Install the PSIR inflator module to the I/P.