Valve Clearance: Adjustments

1.

Remove cam cover.

2.

Torque rocker arm shaft bracket nuts to 16 ft. lbs.

3.

Position No. 1 piston at top dead center, compression stroke. In this position, adjust the following valves to specifications: No. 1 cylinder, intake
and exhaust; No. 2 cylinder, intake; No. 3 cylinder, exhaust.

4.

Rotate crankshaft 360 degrees and adjust the following valves: No. 2 cylinder, exhaust; No. 3 cylinder, intake; No. 4 cylinder, intake and exhaust.

5.

Install cam cover.