Radiator Cooling Fan Motor: Testing and Inspection
Radiator Fan Motor

Fig. 7  Radiator fan motor connector terminal identification

1.

Connect battery positive terminal to radiator fan motor connector terminal 1, Fig. 7.

2.

Ground radiator fan motor connector terminal 2.

3.

Radiator fan should operate. If not check for proper connections, or good ground. Replace fan motor as needed.