isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

ECM/Main Relay <--> [Main Relay (Computer/Fuel System)] > < Intake Air Plenum|Service and Repair
Page 2
background image

Harness Clip

6.

Disconnect induction control vacuum hose, generator cable harness clip, common chamber bracket and engine hanger from common chamber.

7.

Remove common chamber.

REFIT

Common Chamber Removal

Reverse steps to refit noting the following:

Be sure all sealing surfaces are completely clean.
Use a new gaskets.
Tighten common chamber fasteners to 17 ft lb (23 Nm)

Tighten EGR pipe to EGR valve to 32 ft lb (44 Nm)

Tighten EGR pipe to exhaust pipe to 21 ft lb (28 Nm)

Check intake and EGR pipe for leaks.

ECM/Main Relay <--> [Main Relay (Computer/Fuel System)] > < Intake Air Plenum|Service and Repair