Starter Motor: Specifications
Denso 228000-0410 Models, Automatic Transmission

Denso 228000-0410 Models, Automatic Transmission 

No Load Test

Speed

3000 rpm 

Note: Minimum

 

   

  

  

 

Amperes

90 A 

Note: Maximum

 

    

 

  

  

 

Volts

11.5 V 

    

 

  

  

 

Torque Test - Manual transmission

Amperes

300 A 

Note: Maximum

 

   

  

  

 

Volts

2.5 V 

Note: At Torque 5 Ft.Lbs.

 

    

  

 

  

  

 

Torque Test - Automatic transmission

Amperes

350 A 

Note: Maximum

 

   

  

  

 

Volts

8.5 V 

Note: At Torque 8.65 Ft.Lbs.

 

    

  

  

 

  

  

 