Air Door Cable: Adjustments

TEMPERATURE CONTROL CABLE

Temperature Control Adjustment

1. Under the hood, disconnect the heater valve cable from the heater valve.

2. Under the dash, remove the clip and the heater duct from the heater unit.

3. Disconnect the air mix cable housing from the cable clamp.
4. Set the temperature control lever to MAX COOL.
5. With the air mix control cable attached to the air mix control arm, gently pull on the outer cable housing to fully close the door and to remove any

slack in the cable, then snap the air mix control cable housing into the cable clamp.

6. Reinstall the heater duct and the clip on the heater unit.