isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagnostic Aids|Page 13 > < Diagnostic Aids
Page 2
background image

Testing For A Short To Ground With A Self-powered Test Light Or DVOM

1.  Remove the blown fuse and disconnect the battery and load.
2.  Connect one lead of a self-powered test light or Digital Volt/Ohmmeter (DVOM) (switched to the lowest "OHMS" range) to the fuse terminal on

the load side.

3.  Connect the other lead to a known good ground.
4.  Beginning near the fuse box, wiggle the harness. Continue this at convenient points about six inches apart while watching the test light or DVOM.
5.  If the self-powered test light goes on or the DVOM displays a low reading or no reading (0 Volts), there is a short to ground in the wiring near that

point.

Testing for A Short With a Short Circuit Locator (Short Finder)

Testing For A Short With A Short Circuit Locator (short Finder)

1.  Remove the blown fuse. Leave the battery connected.
2.  Connect the short finder across the battery terminals and the load (component) side of the fuse terminal.
3.  Close all switches in the circuit you're testing.
4.  Turn on the short finder. This creates a pulsing magnetic field around the wiring between the fuse box and the short.
5.  Beginning at the fuse box, slowly move the short finder along the circuit wiring. The meter will show current pulses through sheet metal and body

Diagnostic Aids|Page 13 > < Diagnostic Aids